Experiments in the Physiology of Human PerformanceLippincott Williams & Wilkins, 1970 - 208 páginas |
Dentro del libro
Resultados 1-3 de 9
Página 58
... Plethysmograph constructed locally . Inside diameter of base = 32 cm . Plethysmograph factor ( r2 ) = 804.25 ml / cm . Water displacement is noted in cali- brated glass tube shown at left of apparatus . Outlines of segment limits are ...
... Plethysmograph constructed locally . Inside diameter of base = 32 cm . Plethysmograph factor ( r2 ) = 804.25 ml / cm . Water displacement is noted in cali- brated glass tube shown at left of apparatus . Outlines of segment limits are ...
Página 59
... plethysmograph ** For forearm subtract hand wt . Wix Σ = mm X = mm ** Data Sheet 4-1 B. With skin pencil , mark location of wrist joint center . Instruct subject to slowly immerse preferred hand into plethysmograph to joint center ...
... plethysmograph ** For forearm subtract hand wt . Wix Σ = mm X = mm ** Data Sheet 4-1 B. With skin pencil , mark location of wrist joint center . Instruct subject to slowly immerse preferred hand into plethysmograph to joint center ...
Página 63
... plethysmograph ; rectangular plethysmographs would require a formula which includes the area of the base times the height . ) A simpler , slower method of estimating segment volume involves the collecting and weighing of displaced water ...
... plethysmograph ; rectangular plethysmographs would require a formula which includes the area of the base times the height . ) A simpler , slower method of estimating segment volume involves the collecting and weighing of displaced water ...
Contenido
Introduction | 1 |
Somatometry | 17 |
Cardiac Performance and Response to Exercise | 35 |
Derechos de autor | |
Otras 9 secciones no mostradas
Términos y frases comunes
Additional Notes antilog Apparatus and Materials Appendix Approximate Cost assessment Behnke bell bench blood pressure body fat cadence Calculate calibration carbon dioxide cardiac frequency cardiac output chamber circuit cylinder Data Sheet Data Treatment Definition of Terms density diameters Discussion Topics elgon error exhaled Experimental expressed factors force forearm formula function gas sample gasometer goniogram heat Human Performance hydrometer inhalation interval Journal Karpovich Laboratory Exercise Number measurement mercury metabolic meter micrometer minute monitored muscle needle oxygen consumption physical Physiological Plethysmograph position potentiometer probe Procedure pulse rate range of movement reaction reading reagent strips recorder recovery Required Apparatus Ricci rinsing rubber Scholander skinfold thickness Sling psychrometer somatotype specific gravity sphygmomanometer spirogram spirometer stadiometer stethoscope stopcock student sweat switch syringe systolic tape technique temperature tion tissue tubing urine urinometer Vacutainer values vital capacity volume
Referencias a este libro
Proceedings of the Human Factors Society Annual Meeting, Volumen20 Human Factors Society Sin vista previa disponible - 1976 |